APPA 33II Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Měření, testování a kontrola APPA 33II. APPA 33II Instruction manual [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 16
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
CLAMP MULTIMETER

INSTRUCTION MANUAL
APPA 33/33R
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - APPA 33Ⅱ/33RⅡ

CLAMP MULTIMETER INSTRUCTION MANUAL APPA 33Ⅱ/33RⅡ

Strany 2

9 (3) Resistance : Auto - ranging Range Resolution Accuracy Over voltage protection 600V r.m.s. 2000Ω 1Ω ±(1.5%rdg + 2dgt) Max. Open Circuit V

Strany 3 - and 

10 OPERATION This instrument has been designed and tested in accordance with IEC Publication 1010, Safety Require- ments for Electronic Measuring App

Strany 4

11 7. If the meter is used near equipment that generates electromagnetic noise, the display may be unstable or indicate large errors. 8.  Maximum

Strany 5 - Figure 1

12 3-3 AC Voltage Measurement 1. Set the function switch at " V ~ " position. 2. Connect the black test lead to the "COM" termin

Strany 6

13 MAINTENANCE  WARNING : TO AVOID ELECTRICAL SHOCK REMOVE TEST LEAD BEFORE OPENING THE COVER. 4-1 General Maintenance 1. Repairs or servicing not

Strany 7

14 Screw Battery Cover 9V Battery Top Case Bottom Case Figure 2

Strany 8

APPA TECHNOLOGY CORP. 9F.119-1 Pao-Zong Rd., Shin-Tien, Taipai, 23115, Taiwan, R.O.C. P.O.Box. 12-24 Shin-Tien, Taiwan. Tel : 886-2-29178820 Fax : 886

Strany 9

1 INTRODUCTION 1-1 Unpacking and Inspection Upon removing your new Digital Clamp Meter from its packing, you should have the following items: 1. Di

Strany 10

2 Symbols in this Manual  This symbol indicates where cautionary or other information is found in the manual.  Battery. 1-3 Front Panel Refer to Fi

Strany 11

3 5. Trigger — Press the lever to open the transformer jaws. When the pressure on the lever is released, the jaws will close a

Strany 12

4 742183569Figure 1

Strany 13

5 SPECIFICATIONS 2-1 General Specifications Display : 3 1/2 Digital Liquid Crystal Display (LCD) with a maximum reading of 1999. Overrange Indication

Strany 14 - MAINTENANCE

6 Temperature Coefficient : 0.2 x (Spec.Acc'y) / °C , < 18 °C or > 28°C. Power Requirement : Single 9V battery (NEDA 1604,IEC 6F22) Battery

Strany 15

7 2-3 Electrical Specifications Accuracy is ±(%reading + number of digits) at 23 °C ± 5 °C , less than 75% R.H. (1) AC Voltage : Auto-ranging Range

Strany 16 - Printed In Taiwan

8 (2) AC Current : Auto-ranging Range Resolution Accuracy Overload protection 200A 0.1A ±(1.9%rdg + 5dgt) 50/60Hz 600A 1A ±(1.5%rdg +